Most Popular Products
|
Industrial Battery Charger
Industrial Battery Charger Specification
- Ambient Temperature
- 0 to 48 Celsius (oC)
- Suitable For
- Industrial Application
- Power
- 50 - 500 Ampere (amp)
- Product Type
- Electric Charger
- Material
- Copper
- Output Voltage
- As per requirement
- Usage
- Battery
- Rated Frequency
- 50 Hertz (HZ)
- Voltage Range
- 415 +-15% VOLT
- Size
- Customized
- Warranty
- 12 Month
Industrial Battery Charger Trade Information
- Minimum Order Quantity
- 01 Unit
- Supply Ability
- 10 Units Per Month
- Delivery Time
- 30 Days
- Main Domestic Market
- All India
About Industrial Battery Charger
Key Features
- The capability to apply improved charging algorithms to reduce battery water consumption, thereby reducing user maintenance costs.
- The potential to provide a multi-profile charger capability.
- Automatic start when a battery is connected and disconnection when the battery is fully charged.
- Increased product reliability, and reductions in circuit board size and cost.
Product Type - Electric Battery Charger
Usage - Battery Charging
Technical Specifications Of Industrial Battery Charger
| Rating (Amp) | As per customer requirement ( Custom make products ) |
| Cooling | Natural Air Cooled |
| AC input voltage | 415V AC, 3 Phase, 4 Wire. Permissible variation +-10 % |
| AC input frequency | 50 Hz. permissible variations: +2.5 HZ to -3HZ |
| DC output voltage | 110V, 220V , 415V , 440V,650V |
| Current Limit | ADJ. 80% - 100% |
| Power Conversion | AC to DC by means of a three phase full wave |
| Full controlled rectifier consisting of Thyristors/IGBT | |
| Output voltage Regulation | +-1% of set value for a frequency variation of +-2.5 HZ of input frequency, |
| +-10 % input voltage variations & a combined voltage & frequency (absolute | |
| sum) variation | |
| of 10%, 0-100% of load variations. | |
| Efficiency | % 85 90 % at FULL LOAD (At max. Voltage & Current) |
| Ripple voltage | % 1 % PEAK TO PEAK without battery connected. |
| Switchgear: | |
| a) Input side | SWITCH+FUSE+MCCB |
| b) Output Side | MCCB+ SWITCH+FUSE+ MCCB |
| Protection | (a)Surge suppressors (b)Soft start (c)Rectifier protection fuses |
| (d)HRC fuses (e )Control circuit & Voltmeter fuses | |
| Meters | 96 X 96 Sq. mm. analogue meters;- |
| Input voltmeter Output | |
| Voltmeter Output Ammeter | |
| Indications: | INPUT ON LAMPS, OUTPUT ON , |
| LAMP Charger ON, Float LED Charger | |
| ON Boost LED | |
| Alarms | MAINS FAIL |
| OUTPUT UNDER VOLTAGE OUTPUT | |
| OVER VOLTAGE CHARGER FAIL | |
| OVER LOAD GROUND | |
| FAULT | |
| CHARGER TRIP | |
| Operating Temperature | 0- 50 degree centigrade |
| Protection Grade | Suitable for Outdoor / Indoor Installation (IP 65 ) |
| Insulation class | Class F Limited to Class B |
| Insulation Break down | 2.5KV per min |
| voltage | |
| Cables | 1100 V grade PVC insulated copper cables are Used. |
| Average winding | 70C above ambient temp, |
| temp. Rise over | |
| ambient |